LOCAL GATE CONTROLLER ROSSLARE AC-225
Local control unit IN / OUT, IN / IN, 2 reader connections, up to 1000 local controllers on one PC, OFFLINE, 30000 users, built-in power adapter, charger, 4 inputs - 4 outputs, expandable to 12 inputs and 8 outputs, fully programmable and connected via RS-232, RS-485, TCP-IP, in a metal cabinet. ROSSLARE, AC-225.
-
Local control unit IN / OUT, IN / IN, 2 reader connections, up to 1000 local controllers on one PC, OFFLINE, 30000 users, built-in power adapter, charger, 4 inputs - 4 outputs, expandable to 12 inputs and 8 outputs, fully programmable and connected via RS-232, RS-485, TCP-IP, in a metal cabinet. ROSSLARE, AC-225.
ELECTRICAL CHARACTERISTICS
• ACU Power Supply Voltage:
12VDC, regulated from built-in PS-14 regulated power supply / Charger module
• ACU Power Supply Max Current:
Panel output: 500mA input current limitation (PS-14)
Lock output: 1500mA Battery output: 300mA
• Relays:
4 fully programmable 5A, N.O. and N.C. relay outputs 4 expandable outputs with optional MD-IO84
• Battery Charger:
12V sealed lead acid (SLA) up to 7Ah (PS-14)
• Maximum Current for Readers:
300mA at 12VDC O ATIONA PER L CHARACTERISTICS
• Capacity:
30000 Users
• History Event Log Size:
20000 Events
• Inputs:
4 Supervised, dual-resistor, 4 state end-of-line inputs, Hi-impedance, active low 5VDC 8 expandable inputs with optional MD-IO84
• Readers:
Two Wiegand 26/32/34/37/40 bit / C&D reader ports with tamper and LED control, 4,6 and 8 bit burst keypad transmission support
• Connectivity:
RS-485/232, Dial-up (using MD-N33), onboard TCP/IP (AC-225IP version)
• Networking:
32 Units/subnet, 1000 subnets (2000 doors max.) using AS-225 software
• Audio/Visual:
Built-in sounder (Alarm, Chime, Bell), 11 on-board and 3 P.S. LEDs
• Modes of Operation:
Single Door (In/In), Dual Door (In/Out)
• Time Zones and groups:
32 multiple segment time zones, 64 holidays, 1000 access groups
• Anti-Pass Back:
Local and Global anti-pass back (soft / hard), with 'forgive' option
• Special Features:
Interlock, first person delay, auto relock, scheduled outputs operation, 4 programmable site codes, Extended unlocked time, fully interconnectedness.
• Security Modes:
Normal and Secure
• Firmware Upgrade:
Local / Remote, Through AS-225 PC software PH SICAL C Y HARACTERISTICS
• ACU Board Dimensions:
168mm x 121mm (6.61" x 4.76")
• Enclosure:
Metal, locked 326mm x 263mm x 97mm (12.8" x 10.4" x 3.82")
• Weight:
2.4kg (5.3 lbs) ENVIRONMENTAL CHARACTERISTICS
• Operating Environment: Indoor installation only
• Operating Temperature:
0°C to 49°C (32°F to 120°F)
• Operating Humidity:
0 to 85% (non-condensing)
• RFI Protection:
> 20 V/m up to 1000 MHz
Related Products
-
+30 210-6148009
-
Monday – Friday: 08.30-17.00